Since 1939, Crane Engineering has been one of the Midwest's leading providers of fluid process solutions. The company serves a broad range of markets providing fluid system design, equipment sourcing & selection, fabrication, installation, field service and repair.
Pumps, valves, mechanical seals, filters, instruments, controls, water and waste water process equipment.
Pumps, valves, mechanical seals, filters, instruments, controls, water and waste water process equipment.
Crane Engineering Back Pull-Out Repair and Exchange Program
Crane Engineering’s Back Pull-Out Exchange Program helps improve pump reliability, lower the total cost of ownership, and get ahead of failures!
Crane’s BPO program gives customers the opportunity to exchange a failed BPO for a like-new rebuild built by Crane Engineering’s factory-certified service team.
The program focuses on six key points…
1. Pump Reliability
2. Speed
3. Product Application Variability
4. Factory Certified Technicians
5. Quality Control
6. Customer Responsibility
Learn more about the Crane Engineering Back Pull-Out Exchange program at the link below!
hubs.la/Q01ZGf1T0
#CraneEngineering #rebuild #backpullout #exchange #pumpexchange #servicecenter
Crane’s BPO program gives customers the opportunity to exchange a failed BPO for a like-new rebuild built by Crane Engineering’s factory-certified service team.
The program focuses on six key points…
1. Pump Reliability
2. Speed
3. Product Application Variability
4. Factory Certified Technicians
5. Quality Control
6. Customer Responsibility
Learn more about the Crane Engineering Back Pull-Out Exchange program at the link below!
hubs.la/Q01ZGf1T0
#CraneEngineering #rebuild #backpullout #exchange #pumpexchange #servicecenter
Переглядів: 56
Відео
Join Crane Engineering's Team
Переглядів 2572 роки тому
Crane Engineering is a great place for engineers, salespeople, service technicians, and other business professionals who want to build a long-term career. Join our team based in Kimberly, Wisconsin with locations in Burnsville, MN and Grand Rapids, MN.
Precision Repair for Gearboxes
Переглядів 4543 роки тому
Rob Adair walks through the steps for precision rebuild of a gearbox at Crane Engineering's Grand Rapids, MN facility.
Precision Maintenance - Inspecting Shaft
Переглядів 9123 роки тому
Nate does an inspection of a slurry pump shaft to determine if it can be re-used during a pump rebuild.
Precision Maintenance - Overview
Переглядів 34 тис.3 роки тому
Crane Engineering's Joe Frank talks about the importance of precision maintenance when it comes to centrifugal pumps.
Goulds 3196 Power End Precision Repair
Переглядів 3 тис.3 роки тому
Crane Engineering's Service Pros demonstrate what goes into a precision rebuild of a Goulds 3196 power end.
How to Use A Bearing Heater in Precision Maintenance
Переглядів 1,2 тис.3 роки тому
Paul explains how to use a bearing heater and how it is applied in precision maintenance applications.
Precision Rebuilds - Bearings
Переглядів 5503 роки тому
One of Crane's Service Experts, Josh, discusses the important bearing checks required when doing precision maintenance on pumps.
How Minimum Submergence Affects Centrifugal Pumps
Переглядів 1,6 тис.3 роки тому
Minimum submergence is when the liquid level is close enough to the entrance point of the suction pipe that the atmosphere cheats the system, makes a void in the liquid level, enters the pump, and air binds the pump. Watch a video demonstration here.
Challenges with Suction Side Strainers on Centrifugal Pumps
Переглядів 1,1 тис.3 роки тому
Learn the disadvantages of adding a suction-side strainer to centrifugal pumps.
Crane Engineering - Wash Up Work Order Demonstration
Переглядів 2543 роки тому
Rick Ogle demonstrates what happens when additional demand is placed on a centrifugal pump, outside of what it was originally designed.
Inline Blending vs. Batch Processing For Wet Wipe Manufacturing
Переглядів 2933 роки тому
Learn the advantages of converting to inline blending when processing chemicals for wet wipe manufacturing. Inline blending skid systems can provide flexibility during manufacturing and save tremendous amounts of time.
Crane Engineering Tilting Tote Stand
Переглядів 1704 роки тому
Crane Engineering's tilting tote stand drains 100% of product from totes and improves safety versus traditional methods of emptying totes by shimming. The tilting platform is lowered to horizontal position for easy tote changes.
New Products at Crane Engineering
Переглядів 2704 роки тому
Dustin and Ben go over some of our newest product lines at Crane Engineering. You can find these products on our website; www.craneengineering.net/newproducts
Rieger Valves - Product Introduction
Переглядів 1,4 тис.6 років тому
Chris Johnson gives us a brief overview on Rieger Valves, our latest addition to our valve line. These valves are great for CIP sanitary applications. Give us a call at 920-776-4425, or check out our website for more information: www.craneengineering.net.
Gorman-Rupp Eradicator Product Review
Переглядів 3,9 тис.7 років тому
Gorman-Rupp Eradicator Product Review
Goulds Pump Parts - Pump Repair & Maintenance Kit
Переглядів 38 тис.7 років тому
Goulds Pump Parts - Pump Repair & Maintenance Kit
Schoeneck Containers (SCI) i-ALERT2 Success Story
Переглядів 9757 років тому
Schoeneck Containers (SCI) i-ALERT2 Success Story
i-ALERT2 Demo by ITT Goulds Pumps at Crane Engineering Tech Expo 2016
Переглядів 13 тис.8 років тому
i-ALERT2 Demo by ITT Goulds Pumps at Crane Engineering Tech Expo 2016
ITT Goulds Pumps i-ALERT2 Product Overview
Переглядів 1,2 тис.8 років тому
ITT Goulds Pumps i-ALERT2 Product Overview
ITT Goulds Pumps i-ALERT2 Extra Features
Переглядів 6268 років тому
ITT Goulds Pumps i-ALERT2 Extra Features
Crane Engineering Field Service and Repair
Переглядів 6 тис.8 років тому
Crane Engineering Field Service and Repair
Troubleshooting Hunting or Oscillating Valves
Переглядів 9 тис.8 років тому
Troubleshooting Hunting or Oscillating Valves
Indelac Controls Electronic Valve Actuator
Переглядів 2,3 тис.8 років тому
Indelac Controls Electronic Valve Actuator
I didn't understand well enough, unfortunately.
Muy bonito su video ingeniero megustaria saber si tiene un proveedor de refacciones para este modelo de bombas le agradecería mucho
J'aimerais me joindre à vous pour un éventuel poste de mécanicien industriel a pouvoir
I noticed that there is a rise in the suction line immediately before the pump. I’ve always been taught that the suction must always be rising. Can you explain why this is not always the case?
merci tonton tié le sang
Nice demo, thanks!
Great...
The best. ☝️🍋🍸
The first time it draws water, then it releases water, why then the pump quantive runs, it gets hot, please tell
Pls hindi translate
No head preasure
P❤I
Excellent presentation, Joe. That IS precision inspection.
15 to 20 thou on the wear face is a given in the pulp industry, mechanical seals suck!!!!! packing is so much better!! 8$ dollars vs $5k dollars for saved water....
What type of packing would you use for formation water ???
How bout when you have a correct mesh size even then you think the strainer will cause problems
When i checked the shaft runout, i take several points along the shaft, start from coupling end to impeller end, checked the surface condition if any damage on it.
When this is installed do you have to adjust the wear plate?
This is really great, well presented, I bet that guy could easily fill a book with all the knowledge he has.
Surprised there are not more comments
What is the empty hole between the shaft and drain??? Hole above seal cavity drain plug.
I'm thinking its a weep hole if the seal goes out, I'll know more soon, cuz mine is pouring out. LOL
Can I make that rotating assemble tool? I just need the thread size
This a well designed assembly. Kudos to the design and manufacturing team. Any comments from the maintenance engineers among us who have service this type of pump?
Bullshit if it is glogded your dead in the water
It works as designed. Servicing the rotor and stator can take half the time, if not less, depending on your setup and dimensional constraints. As reliable as the legacy models. If ragging is an issue, the service port alone can sometimes prove useful in diagnosing, if not outright clearing the issue.
Great video buddy
Sarah is drop dead gorgeous <3
2 relays relay 1 relay 2 for output.. how to change its contact type default setting NO to NC...
Ribs on the reverse side of the impeller increase strength, but when pumping abrasive water-sand mixtures, this leads to increased wear on the back wall of the pump casing
This is so helpfull
Dear sir, Good morning how are you?? please advise me. explain how to change the oil cell? Best regards, Wasi
Sounds like all might
???????
Thanks guys I'm working for the first time as maintenance personnel and these videos are helping me kill it
Good
Beat pump series.
The music is distracting. The parts on the white display(?) board show no individuality for identification. All the parts look the same. Perhaps this video was made mainly for professionals.
ua-cam.com/video/dUBjCQ-FSq4/v-deo.html
Durco Pump Parts -We manufacture multiple pump parts of ANSI, Goulds, Durco that follow the American National Institute Pump Standard. Contact us today! mosherflopumps.com/pump-sales/
Good
Bad rally bad video
The gentleman says to use a shaft parts kit when the radial bearings are out of tolerance but the caption says when it is NOT out of tolerance.
Yeah, it’s that easy to pull out when it’s brand new without years of gunk jammed up in there.
I have a Gould's submersible pump for the water for inside my house. It's an older one an old.man gave me. He said it can be repaired. The motor runs strong , but the fans or impeller dosent work. Can that be replaced since being the Gould's are so expensive and I need a pump for inside my house because mine quite working.
My cartridge seal is on a sleeve from new. Similar to this one in the video but has a sleeve in the center of cartridge and does not fit on shaft... do I have to remove the sleeve?
Great
Not sure who else to ask but you seem very knowledgable. I'm using a 10" Gorman Rupp self priming prime air pump in a creek that has a huge pool area that I'm pumping out of. The pump primes itself easily but when losing prime, it cannot reprise itself. We've done this many times but never had this problem. The pump will actually pull the water right up to the pump but won't pump. Any suggestions?
im having a similar problem but on a smaller scale.I suspect it is due to binding, i am going to try a air breather valve on the discharge line.
A couple of things could happen here: Discharge check valve worn out. Check valve on ventury line collapse. Suction pipe had a hole in it. Float on the priming chamber is unscrew . Piping from compressor to the priming chamber is worn out.
i need repair kit please do you supplier in egypt
Can you please do a total breakdown and put back for the gt10?
For AC centrifugal pump with a fixed power supply frequency (eg. 50 Hz), if the NPSH required is achieved, is the flow rate constant? Is the liquid flow rate at the rated flow rate on the nameplate?
00923333679286 whtsapp
Gracias amigo me sirvio mucho
Sir how to download PDF file of pump curv